Yasin Standard Green PCTG Green
MaterialID MAT0238

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-13 19:31:28
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | 2026-08-20 |
| Impact | 2026-08-20 |
| Izod | 2026-10-05 |
| Charpy | 2026-10-05 |
| Stiffness | 2026-08-20 |
Complete
6/6
41
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 8,044 MPa | 3,704 MPa | 0,46% | 10 | 10/10 | OK |
| Tensile | Flat | 26,793 MPa | 12,068 MPa | 0,45% | 10 | 10/10 | OK |
| Impact | Upright | 2,656 kJ/m² | 0,768 kJ/m² | 0,289% | 10 | 10/10 | OK |
| Impact | Flat | 9,091 kJ/m² | 1,263 kJ/m² | 0,139% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 1583,796 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 69, 25, 16, 61, 56, 32, 88, 43, 49, 84 |
| Tensile | Flat force inputs (N) | 189, 99, 49, 244, 246, 158, 115, 266, 113, 263 |
| Impact | Upright needle inputs (%) | 4, 3, 2,5, 1,5, 3, 5, 4, 3, 3,5, 3,5 |
| Impact | Flat needle inputs (%) | 12,5, 8,5, 11, 11,5, 10, 10, 10, 12, 13,5, 12,5 |
| Stiffness | Revolutions / degrees | 3 / 85 |
Approved test notes
Method and equipment context
Testing methodology · Engineering methodology whitepaper · Download PDF
Izod and Charpy Impact Strength
Izod Impact Strength · 2026-10-05
Instrument readings in kJ/m²
Mean 2.253 kJ/m²; Std. Dev 0.675 kJ/m²; CV 29.971%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-05
Instrument readings in kJ/m²
Mean 1.286 kJ/m²; Std. Dev 0.143 kJ/m²; CV 11.117%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.