Public test session report

Spectrum Premium Tooling Yellow PLA Yellow

MaterialID MAT0230

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
Tensile2026-08-15
Impact2026-08-15
Stiffness2026-08-15
Status
Complete
Result modules
3/3
Specimen/result records
41
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright18,334 MPa6,728 MPa0,367%1010/10OK
TensileFlat40,698 MPa7,634 MPa0,188%1010/10OK
ImpactUpright140,813 kJ/m²17,104 kJ/m²0,121%1010/10OK
ImpactFlat193,046 kJ/m²19,314 kJ/m²0,1%1010/10OK
StiffnessThree-point bend3237,057 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)176, 73, 149, 133, 86, 88, 84, 177, 158, 68
TensileFlat force inputs (N)204, 320, 349, 190, 281, 242, 289, 274, 229, 268
ImpactUpright needle inputs (%)7, 7, 7,5, 8, 10, 9, 8,5, 8,5, 9,5, 8,5
ImpactFlat needle inputs (%)9,5, 12, 11,5, 11, 10, 11,5, 11,5, 11, 13, 13
StiffnessRevolutions / degrees1 / 210

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF