Public test session report

Spectrum Premium Forest Green ABS Green

MaterialID MAT0228

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
Tensile2026-08-15
Impact2026-08-16
Stiffness2026-08-15
Status
Complete
Result modules
3/3
Specimen/result records
39
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright2,249 MPa1,598 MPa0,711%88/10OK
TensileFlat21,456 MPa5,747 MPa0,268%1010/10OK
ImpactUpright127,194 kJ/m²27,041 kJ/m²0,213%1010/10OK
ImpactFlat1041,865 kJ/m²75,928 kJ/m²0,073%1010/10OK
StiffnessThree-point bend941,389 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)10, 35, 9, 9, 7, 27, 11, 9, ,
TensileFlat force inputs (N)160, 133, 179, 136, 90, 178, 78, 105, 169, 167
ImpactUpright needle inputs (%)4, 7, 9, 7,5, 7, 8, 8,5, 10, 7, 7,5
ImpactFlat needle inputs (%)55, 67, 67, 77, 75, 65, 67, 88, 75, 72
StiffnessRevolutions / degrees5 / 160

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF