Eryone Standard Radiant Gold PLA Silk Yellow
MaterialID MAT0219

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-13 19:31:28
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | 2026-07-31 |
| Impact | 2026-08-01 |
| Izod | 2026-10-11 |
| Charpy | 2026-10-11 |
| Stiffness | 2026-07-31 |
Complete
6/6
36
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 2,666 MPa | 1,154 MPa | 0,433% | 6 | 6/10 | OK |
| Tensile | Flat | 29,5 MPa | 10,289 MPa | 0,349% | 10 | 10/10 | OK |
| Impact | Upright | 3,956 kJ/m² | 0,688 kJ/m² | 0,174% | 10 | 10/10 | OK |
| Impact | Flat | 10,207 kJ/m² | 0,925 kJ/m² | 0,091% | 9 | 9/10 | OK |
| Stiffness | Three-point bend | 2027,607 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 16, 21, 28, 21, 9, 9, , , , |
| Tensile | Flat force inputs (N) | 241, 183, 277, 145, 72, 214, 236, 135, 270, 145 |
| Impact | Upright needle inputs (%) | 4, 4, 4, 5, 6, 4,5, 5, 5, 5, 6,5 |
| Impact | Flat needle inputs (%) | 10, 12, 12,5, 12, 13, 13, 13, 13, 14, |
| Stiffness | Revolutions / degrees | 2 / 190 |
Approved test notes
Method and equipment context
Testing methodology · Engineering methodology whitepaper · Download PDF
Izod and Charpy Impact Strength
Charpy Impact Strength · 2026-10-11
Instrument readings in kJ/m²
Mean 6.24 kJ/m²; Std. Dev 2.133 kJ/m²; CV 34.182%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-11
Instrument readings in kJ/m²
Mean 3.515 kJ/m²; Std. Dev 0.524 kJ/m²; CV 14.917%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.