Public test session report

Eryone Standard Black PA12 CF Black

MaterialID MAT0214

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
Tensile2026-08-01
Impact2026-08-01
Stiffness2026-08-01
Status
Complete
Result modules
3/3
Specimen/result records
41
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright4,337 MPa2,458 MPa0,567%1010/10OK
TensileFlat64,323 MPa6,022 MPa0,094%1010/10OK
ImpactUpright161,328 kJ/m²14,235 kJ/m²0,088%1010/10OK
ImpactFlat749,286 kJ/m²37,669 kJ/m²0,05%1010/10OK
StiffnessThree-point bend2674,09 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)18, 18, 48, 38, 20, 26, 50, 9, 46, 9
TensileFlat force inputs (N)428, 420, 436, 435, 445, 474, 441, 378, 384, 341
ImpactUpright needle inputs (%)9, 10, 9, 10, 9,5, 8, 10, 9, 10, 11
ImpactFlat needle inputs (%)48, 43, 43, 45, 47, 45, 45, 48, 49, 41
StiffnessRevolutions / degrees1 / 330

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF