Public test session report

Eryone Standard Black PA6 GF Black

MaterialID MAT0210

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
Impact2026-08-02
Stiffness2026-08-01
Status
Partial
Result modules
2/3
Specimen/result records
21
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUprightn/an/an/a0n/aOK
TensileFlatn/an/an/a0n/aOK
ImpactUpright105,069 kJ/m²25,669 kJ/m²0,244%1010/10OK
ImpactFlat695,775 kJ/m²47,255 kJ/m²0,068%1010/10OK
StiffnessThree-point bend3181,245 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N), , , , , , , , ,
TensileFlat force inputs (N), , , , , , , , ,
ImpactUpright needle inputs (%)3, 7, 8, 5,5, 6, 6, 8, 5, 7, 7
ImpactFlat needle inputs (%)41, 49, 41, 42, 40, 38, 44, 44, 39, 40
StiffnessRevolutions / degrees1 / 220

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF