Public test session report

BambuLab Standard White Marble PLA Marble White

MaterialID MAT0177

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
StiffnessNot recorded
Status
Complete
Result modules
3/3
Specimen/result records
40
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright11,45 MPa3,945 MPa0,345%99/10OK
TensileFlat32,254 MPa4,142 MPa0,128%1010/10OK
ImpactUpright118,686 kJ/m²28,407 kJ/m²0,239%1010/10OK
ImpactFlat756,732 kJ/m²127,416 kJ/m²0,168%1010/10OK
StiffnessThree-point bend2120,83 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)57, 100, 50, 101, 72, 26, 83, 85, 96,
TensileFlat force inputs (N)216, 238, 216, 236, 182, 162, 182, 235, 200, 230
ImpactUpright needle inputs (%)3, 6,5, 8, 8, 7, 7, 9, 8, 8, 6
ImpactFlat needle inputs (%)34, 59, 50, 35, 52, 53, 55, 45, 43, 37
StiffnessRevolutions / degrees2 / 150

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF