BambuLab Standard Black Walnut PLA Wood Brown
MaterialID MAT0175

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-13 19:31:28
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Izod | 2026-10-13 |
| Charpy | 2026-10-13 |
| Stiffness | Not recorded |
Complete
6/6
39
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 3,538 MPa | 1,777 MPa | 0,502% | 8 | 8/10 | OK |
| Tensile | Flat | 31,746 MPa | 4,37 MPa | 0,138% | 10 | 10/10 | OK |
| Impact | Upright | 5,88 kJ/m² | 1,422 kJ/m² | 0,242% | 10 | 10/10 | OK |
| Impact | Flat | 11,697 kJ/m² | 2,076 kJ/m² | 0,177% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2510,37 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 42, 18, 12, 30, 8, 25, 16, 33, , |
| Tensile | Flat force inputs (N) | 182, 227, 214, 211, 161, 232, 231, 221, 226, 159 |
| Impact | Upright needle inputs (%) | 4,5, 8,5, 8, 8, 5, 7,5, 9, 9, 8, 5 |
| Impact | Flat needle inputs (%) | 17, 17, 17, 13, 11, 15, 10,5, 12, 15,5, 15 |
| Stiffness | Revolutions / degrees | 2 / 15 |
Approved test notes
Method and equipment context
Testing methodology · Engineering methodology whitepaper · Download PDF
Izod and Charpy Impact Strength
Charpy Impact Strength · 2026-10-13
Instrument readings in kJ/m²
Mean 4.749 kJ/m²; Std. Dev 0.15 kJ/m²; CV 3.148%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-13
Instrument readings in kJ/m²
Mean 4.609 kJ/m²; Std. Dev 0.079 kJ/m²; CV 1.714%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.