Winkle Standard Ash Gray PETG Gray
MaterialID MAT0165

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-13 19:31:28
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Izod | 2026-10-06 |
| Charpy | 2026-10-06 |
| Stiffness | Not recorded |
Complete
6/6
41
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 15,488 MPa | 4,127 MPa | 0,266% | 10 | 10/10 | OK |
| Tensile | Flat | 32,9 MPa | 5,799 MPa | 0,176% | 10 | 10/10 | OK |
| Impact | Upright | 6,083 kJ/m² | 0,821 kJ/m² | 0,135% | 10 | 10/10 | OK |
| Impact | Flat | 7,647 kJ/m² | 1,257 kJ/m² | 0,164% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 1708,447 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 129, 110, 78, 115, 66, 120, 68, 80, 98, 143 |
| Tensile | Flat force inputs (N) | 210, 252, 240, 154, 239, 237, 253, 154, 186, 214 |
| Impact | Upright needle inputs (%) | 7,00, 8,50, 8,00, 7,50, 6,00, 7,00, 8,00, 6,00, 9,00, 8,00 |
| Impact | Flat needle inputs (%) | 10,00, 9,00, 8,00, 11,00, 9,00, 8,00, 10,00, 9,00, 7,50, 12,50 |
| Stiffness | Revolutions / degrees | 3 / 0 |
Approved test notes
Method and equipment context
Testing methodology · Engineering methodology whitepaper · Download PDF
Izod and Charpy Impact Strength
Charpy Impact Strength · 2026-10-06
Instrument readings in kJ/m²
Mean 2.684 kJ/m²; Std. Dev 0.122 kJ/m²; CV 4.553%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-06
Instrument readings in kJ/m²
Mean 3.756 kJ/m²; Std. Dev 0.103 kJ/m²; CV 2.755%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.