Public test session report

Winkle Standard Smokey Gray PLA Matte Gray

MaterialID MAT0158

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
StiffnessNot recorded
Status
Complete
Result modules
3/3
Specimen/result records
41
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright7,49 MPa2,36 MPa0,315%1010/10OK
TensileFlat33,884 MPa6,338 MPa0,187%1010/10OK
ImpactUpright133,129 kJ/m²15,459 kJ/m²0,116%1010/10OK
ImpactFlat706,673 kJ/m²33,165 kJ/m²0,047%1010/10OK
StiffnessThree-point bend1962,896 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)49, 46, 46, 48, 68, 55, 60, 26, 67, 22
TensileFlat force inputs (N)140, 252, 261, 196, 195, 247, 256, 234, 247, 175
ImpactUpright needle inputs (%)6,00, 7,50, 8,00, 8,00, 8,50, 9,00, 9,00, 8,00, 7,00, 8,00
ImpactFlat needle inputs (%)42,00, 39,00, 41,00, 43,00, 44,00, 43,00, 43,00, 40,00, 43,00, 47,00
StiffnessRevolutions / degrees2 / 220

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF