Public test session report
Winkle Standard Recycled PLA Recycled Gray
MaterialID MAT0157

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Stiffness | Not recorded |
Status
Complete
Complete
Result modules
3/3
3/3
Specimen/result records
41
41
Public details
Approved
Approved
Specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 13,304 MPa | 6,044 MPa | 0,454% | 10 | 10/10 | OK |
| Tensile | Flat | 41,974 MPa | 6,491 MPa | 0,155% | 10 | 10/10 | OK |
| Impact | Upright | 158,776 kJ/m² | 23,095 kJ/m² | 0,145% | 10 | 10/10 | OK |
| Impact | Flat | 231,696 kJ/m² | 18,589 kJ/m² | 0,08% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2976,004 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 125, 116, 64, 105, 14, 104, 112, 63, 125, 37 |
| Tensile | Flat force inputs (N) | 244, 309, 250, 303, 260, 324, 202, 305, 224, 308 |
| Impact | Upright needle inputs (%) | 8,00, 8,50, 11,50, 9,50, 9,50, 10,00, 10,00, 11,00, 9,00, 7,00 |
| Impact | Flat needle inputs (%) | 12,00, 12,50, 15,00, 14,00, 14,50, 13,00, 15,00, 12,50, 14,00, 14,00 |
| Stiffness | Revolutions / degrees | 1 / 260 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF