Public test session report

Winkle Standard Recycled PLA Recycled Gray

MaterialID MAT0157

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
StiffnessNot recorded
Status
Complete
Result modules
3/3
Specimen/result records
41
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright13,304 MPa6,044 MPa0,454%1010/10OK
TensileFlat41,974 MPa6,491 MPa0,155%1010/10OK
ImpactUpright158,776 kJ/m²23,095 kJ/m²0,145%1010/10OK
ImpactFlat231,696 kJ/m²18,589 kJ/m²0,08%1010/10OK
StiffnessThree-point bend2976,004 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)125, 116, 64, 105, 14, 104, 112, 63, 125, 37
TensileFlat force inputs (N)244, 309, 250, 303, 260, 324, 202, 305, 224, 308
ImpactUpright needle inputs (%)8,00, 8,50, 11,50, 9,50, 9,50, 10,00, 10,00, 11,00, 9,00, 7,00
ImpactFlat needle inputs (%)12,00, 12,50, 15,00, 14,00, 14,50, 13,00, 15,00, 12,50, 14,00, 14,00
StiffnessRevolutions / degrees1 / 260

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF