Public test session report

Thorwell Standard Wood PLA Wood Brown

MaterialID MAT0153

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-13 19:31:28

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
Izod2026-10-10
Charpy2026-10-10
StiffnessNot recorded
Rigid test status
Complete
Rigid result modules
6/6
Rigid specimen/result records
39
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright2,576 MPa0,929 MPa0,361%88/10OK
TensileFlat21,549 MPa4,34 MPa0,201%1010/10OK
ImpactUpright8,471 kJ/m²1,042 kJ/m²0,123%1010/10OK
ImpactFlat11,945 kJ/m²1,363 kJ/m²0,114%1010/10OK
StiffnessThree-point bend2493,408 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)13, 14, 22, 22, 26, 17, 11, 9, ,
TensileFlat force inputs (N)110, 179, 180, 123, 140, 174, 114, 140, 109, 132
ImpactUpright needle inputs (%)11,00, 7,00, 10,00, 10,00, 11,00, 11,00, 11,00, 11,00, 11,00, 11,00
ImpactFlat needle inputs (%)15,00, 16,00, 14,00, 17,00, 12,00, 12,00, 15,00, 15,00, 14,00, 16,00
StiffnessRevolutions / degrees2 / 20

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Izod and Charpy Impact Strength

Izod Impact Strength · 2026-10-10
Instrument readings in kJ/m²
Mean 3.49 kJ/m²; Std. Dev 0.274 kJ/m²; CV 7.857%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Charpy Impact Strength · 2026-10-10
Instrument readings in kJ/m²
Mean 3.013 kJ/m²; Std. Dev 0.055 kJ/m²; CV 1.838%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.