Public test session report

Add:North Enhanced PLA Clear

MaterialID MAT0122

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
StiffnessNot recorded
Status
Complete
Result modules
3/3
Specimen/result records
41
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright24,163 MPa2,838 MPa0,117%1010/10OK
TensileFlat39,882 MPa1,646 MPa0,041%1010/10OK
ImpactUpright45,051 kJ/m²7,071 kJ/m²0,157%1010/10OK
ImpactFlat164,754 kJ/m²15,758 kJ/m²0,096%1010/10OK
StiffnessThree-point bend2753,914 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)155, 166, 152, 111, 153, 172, 162, 153, 176, 171
TensileFlat force inputs (N)277, 263, 246, 271, 264, 253, 261, 264, 247, 247
ImpactUpright needle inputs (%)2,00, 3,00, 3,00, 2,00, 3,00, 2,50, 3,00, 3,00, 2,50, 3,00
ImpactFlat needle inputs (%)11,00, 8,00, 9,50, 11,00, 10,00, 10,00, 9,00, 10,00, 10,00, 9,00
StiffnessRevolutions / degrees1 / 310

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF