Public test session report

Winkle Standard PLA HD Blue

MaterialID MAT0120

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
StiffnessNot recorded
Status
Partial
Result modules
1/3
Specimen/result records
20
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUprightn/an/an/a0n/aOK
TensileFlatn/an/an/a0n/aOK
ImpactUpright33,343 kJ/m²15,797 kJ/m²0,474%1010/10OK
ImpactFlat98,232 kJ/m²9,84 kJ/m²0,1%1010/10OK
StiffnessThree-point bendn/an/an/a0OK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N), , , , , , , , ,
TensileFlat force inputs (N), , , , , , , , ,
ImpactUpright needle inputs (%)1,00, 1,00, 2,50, 1,50, 2,50, 1,00, 2,00, 2,50, 4,00, 2,00
ImpactFlat needle inputs (%)6,00, 6,00, 5,00, 6,00, 6,00, 7,00, 6,00, 5,50, 5,00, 6,00
StiffnessRevolutions / degrees

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF