Public test session report
Polymaker PolySonic PLA Black
MaterialID MAT0110

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Stiffness | Not recorded |
Status
Complete
Complete
Result modules
3/3
3/3
Specimen/result records
41
41
Public details
Approved
Approved
Specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 14,043 MPa | 5,106 MPa | 0,364% | 10 | 10/10 | OK |
| Tensile | Flat | 26,286 MPa | 2,976 MPa | 0,113% | 10 | 10/10 | OK |
| Impact | Upright | 106,726 kJ/m² | 11,369 kJ/m² | 0,107% | 10 | 10/10 | OK |
| Impact | Flat | 242,007 kJ/m² | 31,447 kJ/m² | 0,13% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2562,67 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 99, 83, 107, 46, 70, 127, 141, 60, 124, 56 |
| Tensile | Flat force inputs (N) | 188, 178, 183, 150, 171, 192, 152, 149, 197, 149 |
| Impact | Upright needle inputs (%) | 5,50, 5,50, 6,00, 6,50, 6,00, 6,50, 6,00, 7,50, 7,00, 7,00 |
| Impact | Flat needle inputs (%) | 13,00, 12,50, 13,50, 18,00, 14,00, 14,00, 12,50, 16,00, 16,00, 13,00 |
| Stiffness | Revolutions / degrees | 2 / 0 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF