Public test session report

Prima Creator PrimaValue Light Gray PLA Plus Gray

MaterialID MAT0096

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-13 19:31:28

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
Izod2026-10-10
Charpy2026-10-10
StiffnessNot recorded
Rigid test status
Complete
Rigid result modules
6/6
Rigid specimen/result records
41
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright13,535 MPa5,586 MPa0,413%1010/10OK
TensileFlat39,898 MPa3,061 MPa0,077%1010/10OK
ImpactUpright10,704 kJ/m²1,377 kJ/m²0,129%1010/10OK
ImpactFlat45,302 kJ/m²1,218 kJ/m²0,027%1010/10OK
StiffnessThree-point bend2460,163 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)120, 59, 126, 94, 58, 118, 42, 143, 63, 57
TensileFlat force inputs (N)260, 267, 273, 269, 276, 216, 262, 231, 274, 266
ImpactUpright needle inputs (%)14,00, 15,00, 11,00, 12,00, 11,00, 16,00, 12,00, 14,00, 13,00, 13,00
ImpactFlat needle inputs (%)55,00, 60,00, 61,00, 60,00, 60,00, 60,00, 60,00, 60,00, 60,00, 64,00
StiffnessRevolutions / degrees2 / 30

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Izod and Charpy Impact Strength

Charpy Impact Strength · 2026-10-10
Instrument readings in kJ/m²
Mean 16.841 kJ/m²; Std. Dev 0.351 kJ/m²; CV 2.083%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Izod Impact Strength · 2026-10-10
Instrument readings in kJ/m²
Mean 14.291 kJ/m²; Std. Dev 0.567 kJ/m²; CV 3.968%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.