Public test session report

Polymaker PolyTerra PLA Black

MaterialID MAT0095

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
StiffnessNot recorded
Status
Complete
Result modules
3/3
Specimen/result records
41
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright6,814 MPa1,291 MPa0,189%1010/10OK
TensileFlat19,903 MPa3,483 MPa0,175%1010/10OK
ImpactUpright119,487 kJ/m²12,564 kJ/m²0,105%1010/10OK
ImpactFlat322,729 kJ/m²21,17 kJ/m²0,066%1010/10OK
StiffnessThree-point bend1845,122 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)48, 47, 39, 53, 26, 52, 53, 39, 45, 41
TensileFlat force inputs (N)112, 160, 119, 85, 119, 138, 142, 150, 119, 150
ImpactUpright needle inputs (%)6,00, 7,00, 8,00, 7,00, 7,00, 8,00, 7,00, 7,00, 8,00, 6,00
ImpactFlat needle inputs (%)20,00, 18,00, 20,00, 19,50, 20,50, 20,00, 17,50, 17,00, 18,00, 19,00
StiffnessRevolutions / degrees2 / 280

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF