Public test session report
Polymaker PolyLight PLA Pro Black
MaterialID MAT0079

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Stiffness | Not recorded |
Status
Complete
Complete
Result modules
3/3
3/3
Specimen/result records
41
41
Public details
Approved
Approved
Specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 23,456 MPa | 4,86 MPa | 0,207% | 10 | 10/10 | OK |
| Tensile | Flat | 33,13 MPa | 5,755 MPa | 0,174% | 10 | 10/10 | OK |
| Impact | Upright | 143,39 kJ/m² | 23,468 kJ/m² | 0,164% | 10 | 10/10 | OK |
| Impact | Flat | 889,783 kJ/m² | 88,086 kJ/m² | 0,099% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2527,565 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 191, 158, 148, 81, 133, 164, 176, 130, 174, 170 |
| Tensile | Flat force inputs (N) | 241, 194, 187, 242, 244, 222, 125, 233, 231, 235 |
| Impact | Upright needle inputs (%) | 8,00, 9,50, 9,00, 8,00, 9,00, 10,50, 7,00, 8,00, 6,00, 10,00 |
| Impact | Flat needle inputs (%) | 67,00, 59,00, 61,00, 54,00, 59,00, 52,00, 61,00, 55,00, 42,00, 51,00 |
| Stiffness | Revolutions / degrees | 2 / 10 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF