Public test session report
BambuLab Tough+ PLA Tough+ Black
MaterialID MAT0076

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Stiffness | Not recorded |
Status
Complete
Complete
Result modules
3/3
3/3
Specimen/result records
41
41
Public details
Approved
Approved
Specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 17,396 MPa | 3,052 MPa | 0,175% | 10 | 10/10 | OK |
| Tensile | Flat | 23,933 MPa | 1,434 MPa | 0,06% | 10 | 10/10 | OK |
| Impact | Upright | 201,636 kJ/m² | 25,203 kJ/m² | 0,125% | 10 | 10/10 | OK |
| Impact | Flat | 975,075 kJ/m² | 42,651 kJ/m² | 0,044% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 1962,896 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 99, 133, 143, 94, 100, 98, 132, 106, 92, 134 |
| Tensile | Flat force inputs (N) | 141, 151, 163, 157, 141, 161, 165, 162, 150, 165 |
| Impact | Upright needle inputs (%) | 10,00, 13,00, 11,00, 12,00, 14,00, 11,00, 9,50, 13,00, 12,50, 13,00 |
| Impact | Flat needle inputs (%) | 61,00, 65,00, 66,00, 67,00, 70,00, 58,00, 65,00, 62,00, 59,00, 59,00 |
| Stiffness | Revolutions / degrees | 2 / 220 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF