Public test session report
Prusa3D Prusament PC Blend PC Black
MaterialID MAT0033

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Stiffness | Not recorded |
Status
Complete
Complete
Result modules
3/3
3/3
Specimen/result records
41
41
Public details
Approved
Approved
Specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 17,673 MPa | 3,075 MPa | 0,174% | 10 | 10/10 | OK |
| Tensile | Flat | 43,928 MPa | 1,09 MPa | 0,025% | 10 | 10/10 | OK |
| Impact | Upright | 61,026 kJ/m² | 7,986 kJ/m² | 0,131% | 10 | 10/10 | OK |
| Impact | Flat | 855,617 kJ/m² | 164,425 kJ/m² | 0,192% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2038,809 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 82, 119, 119, 110, 99, 118, 144, 127, 140, 91 |
| Tensile | Flat force inputs (N) | 298, 296, 278, 287, 290, 282, 280, 283, 278, 284 |
| Impact | Upright needle inputs (%) | 3,00, 3,50, 4,00, 4,00, 3,00, 3,00, 4,00, 4,00, 4,00, 4,00 |
| Impact | Flat needle inputs (%) | 65,00, 60,00, 57,00, 54,00, 51,00, 39,00, 63,00, 67,00, 29,00, 55,00 |
| Stiffness | Revolutions / degrees | 2 / 185 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF