Public test session report
Prima Creator PrimaSelect PC Black
MaterialID MAT0032

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Stiffness | Not recorded |
Status
Complete
Complete
Result modules
3/3
3/3
Specimen/result records
41
41
Public details
Approved
Approved
Specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 6,521 MPa | 2,36 MPa | 0,362% | 10 | 10/10 | OK |
| Tensile | Flat | 35,007 MPa | 12,401 MPa | 0,354% | 10 | 10/10 | OK |
| Impact | Upright | 159,64 kJ/m² | 26,576 kJ/m² | 0,166% | 10 | 10/10 | OK |
| Impact | Flat | 251,463 kJ/m² | 28,418 kJ/m² | 0,113% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2654,852 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 61, 34, 32, 54, 47, 33, 53, 44, 10, 56 |
| Tensile | Flat force inputs (N) | 270, 325, 182, 296, 220, 278, 118, 181, 309, 97 |
| Impact | Upright needle inputs (%) | 10,00, 8,00, 9,50, 9,00, 11,00, 10,00, 12,00, 6,50, 8,50, 10,00 |
| Impact | Flat needle inputs (%) | 15,50, 16,00, 12,50, 13,00, 16,00, 14,00, 18,00, 14,50, 15,00, 13,50 |
| Stiffness | Revolutions / degrees | 1 / 335 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF