Public test session report
Prima Creator PrimaSelect PC CF Black
MaterialID MAT0028

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Stiffness | Not recorded |
Status
Complete
Complete
Result modules
3/3
3/3
Specimen/result records
41
41
Public details
Approved
Approved
Specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 5,106 MPa | 3,281 MPa | 0,643% | 10 | 10/10 | OK |
| Tensile | Flat | 55,433 MPa | 5,958 MPa | 0,107% | 10 | 10/10 | OK |
| Impact | Upright | 88,994 kJ/m² | 33,931 kJ/m² | 0,381% | 10 | 10/10 | OK |
| Impact | Flat | 338,738 kJ/m² | 75,23 kJ/m² | 0,222% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2674,09 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 51, 28, 67, 9, 58, 17, 46, 16, 33, 7 |
| Tensile | Flat force inputs (N) | 380, 355, 362, 385, 278, 416, 382, 354, 375, 317 |
| Impact | Upright needle inputs (%) | 3,00, 6,00, 3,00, 3,00, 5,00, 8,00, 7,00, 4,00, 6,00, 8,00 |
| Impact | Flat needle inputs (%) | 26,00, 13,00, 19,00, 27,00, 15,00, 17,00, 21,00, 22,00, 19,00, 20,00 |
| Stiffness | Revolutions / degrees | 1 / 330 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF