Public test session report
Extrudr DuraPro PA12 Black
MaterialID MAT0020

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Stiffness | Not recorded |
Status
Complete
Complete
Result modules
3/3
3/3
Specimen/result records
40
40
Public details
Approved
Approved
Specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 16,372 MPa | 3,881 MPa | 0,237% | 9 | 9/10 | OK |
| Tensile | Flat | 38,252 MPa | 3,131 MPa | 0,082% | 10 | 10/10 | OK |
| Impact | Upright | 211,94 kJ/m² | 26,857 kJ/m² | 0,127% | 10 | 10/10 | OK |
| Impact | Flat | 794,527 kJ/m² | 170,469 kJ/m² | 0,215% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 1118,256 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 78, 141, 87, 133, 117, 120, 114, 102, 66, |
| Tensile | Flat force inputs (N) | 255, 230, 260, 206, 256, 250, 280, 265, 245, 240 |
| Impact | Upright needle inputs (%) | 13,00, 12,00, 14,50, 11,00, 13,00, 15,00, 11,00, 10,00, 12,50, 13,00 |
| Impact | Flat needle inputs (%) | 62,00, 28,00, 47,00, 60,00, 46,00, 62,00, 34,00, 62,00, 48,00, 45,00 |
| Stiffness | Revolutions / degrees | 4 / 210 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF