Public test session report

Yasin Standard White ASA White

MaterialID MAT0017

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-13 19:31:28

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
Izod2026-10-06
Charpy2026-10-06
StiffnessNot recorded
Rigid test status
Complete
Rigid result modules
6/6
Rigid specimen/result records
41
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright6,075 MPa1,998 MPa0,329%1010/10OK
TensileFlat27,716 MPa3,41 MPa0,123%1010/10OK
ImpactUpright6,659 kJ/m²1,198 kJ/m²0,18%1010/10OK
ImpactFlat42,879 kJ/m²1,056 kJ/m²0,025%1010/10OK
StiffnessThree-point bend1563,663 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)46, 20, 43, 35, 37, 65, 46, 48, 26, 29
TensileFlat force inputs (N)190, 185, 199, 204, 162, 139, 209, 160, 184, 170
ImpactUpright needle inputs (%)7,00, 7,00, 9,50, 9,50, 10,00, 10,00, 8,00, 8,00, 6,00, 7,00
ImpactFlat needle inputs (%)57,00, 58,00, 58,00, 57,00, 55,00, 56,00, 54,00, 53,00, 54,00, 56,00
StiffnessRevolutions / degrees3 / 100

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Izod and Charpy Impact Strength

Izod Impact Strength · 2026-10-06
Instrument readings in kJ/m²
Mean 30.509 kJ/m²; Std. Dev 10.463 kJ/m²; CV 34.294%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Charpy Impact Strength · 2026-10-06
Instrument readings in kJ/m²
Mean 33.355 kJ/m²; Std. Dev 17.697 kJ/m²; CV 53.056%; Samples 8; Confidence 8
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.