Public printing recommendation

Prima Creator PrimaValue PLA Lightweight Black

MaterialID MAT0102

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-13 19:33:00

Guidance boundary: values below are shared base-material guidance resolved only through the canonical BaseMaterialId link. They are not manufacturer-, spool- or printer-specific validated settings. Missing fields remain Not recorded.
Overall
39/100
Engineering axes
7/8
Public rank
135 / 166
MSRP USD/kg
27.74

Engineering profile

Overall
39/100
Tensile
15/100
Impact
—
Izod
15/100
Charpy
21/100
Stiffness
52/100
Consistency
76/100
Layer adhesion
35/100

Recommended applications

  • Repeatable print jobs and production-style batches
  • Cosmetic parts, concept models or low-load prototypes
  • Avoid high tensile load applications
  • Avoid high impact components

Measured strengths

  • Consistency: 76/100. Repeatability is one of the stronger signals in this material profile.
  • Izod/Charpy impact family: 18/100. The two-method impact score is competitive against the material-family context.

Limitations

  • Tensile: 15/100. Avoid using this as the primary choice for tensile-loaded parts.
  • Izod/Charpy impact family: 18/100. Validate impact or shock-loaded components against their application requirements.
  • Stiffness: 52/100. Expect less shape stability than the stronger materials in the same family.
  • Layer adhesion: 35/100. Z-axis performance should be treated with caution.

Engineering trade-offs

  • Good repeatability does not compensate for low tensile capability in load-bearing designs.
  • The report should be read as a suitability warning rather than a general-purpose recommendation.

Base-material printing guidance

GuidanceMinimumRecommendedMaximumUnit
Nozzle temperature195230230°C
Bed temperature606070°C
Print speed55165165mm/s
Cooling208085%
GuidanceValueUnit
Cooling guidanceHigh
Drying temperature50°C
Drying time5hours
EnclosureNot required
Printer / G-code referencePrusaCoreOneL
Slicer profile referencePrusament PLA

Print workflow checks

Decision guidance

Stronger same-family alternatives

MaterialIDMaterialManufacturerOverallTensileImpactIzodCharpy
MAT0265Coex 3D Standard Scarlet Red PLA RedCoex 3D58/10039/100—n/an/a
MAT0066ProtoPasta HTPLA Cloverleaf Metallic Green PLA Metal GreenProtoPasta56/10029/100—n/an/a
MAT0118Prusa3D Prusament Azure Blue PLA BluePrusa3D55/10036/100—n/an/a
Confirm exact settings against the manufacturer profile, spool label and actual printer/material combination. Results do not replace application-specific validation.

Testing methodology · Download PDF

Izod and Charpy Impact Strength

Izod Impact Strength · 2026-10-10
Instrument readings in kJ/m²
Mean 12.251 kJ/m²; Std. Dev 3.446 kJ/m²; CV 28.125%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Charpy Impact Strength · 2026-10-10
Instrument readings in kJ/m²
Mean 16.707 kJ/m²; Std. Dev 2.284 kJ/m²; CV 13.67%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Izod Impact Strength · run 3 · 2026-09-21 · Condition 1 · All batches
Printed on long side; bed-facing surface and layer/notch directions unconfirmed; specimen: ; notch: Unconfirmed
Standard reference: ISO 180 (reference only); Unverified comparative measurement; standard reference is not confirmed conformity
Measured 0/10 run target; valid complete-break n=0; mean n/a kJ/m²; sample SD n/a kJ/m²; CV n/a%; min n/a; max n/a kJ/m²
No break 0; invalid 0; excluded 0. Conditions and runs are separate. Batch rows overlap their condition total; do not sum them.

Score policy engineering-score-v70-1: Overall requires tensile, stiffness, consistency, layer adhesion and the Izod/Charpy impact family, each with equal weight. Both impact methods and configured versioned references are required. Missing results and unconfigured scores remain n/a. Legacy Impact is historical only; thermal remains separate. Engineering-axis counts describe displayed evidence, not Overall completeness.