Public printing recommendation
Polyalchemy Elexir Fire PLA Silk Red
MaterialID MAT0092

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:05:46
Guidance boundary: values below are shared base-material guidance resolved only through the canonical BaseMaterialId link. They are not manufacturer-, spool- or printer-specific validated settings. Missing fields remain Not recorded.
Overall
29/100
29/100
Engineering axes
5/5
5/5
Public rank
234 / 234
234 / 234
MSRP USD/kg
25.00
25.00
Engineering profile
Recommended applications
- Cosmetic parts, concept models or low-load prototypes
- Avoid high tensile load applications
- Avoid high impact components
Measured strengths
- Best available signal: Stiffness at 56/100.
Limitations
- Tensile: 18/100. Avoid using this as the primary choice for tensile-loaded parts.
- Impact: 10/100. Avoid high impact or shock-loaded components without additional validation.
- Stiffness: 56/100. Expect less shape stability than the stronger materials in the same family.
- Consistency: 49/100. Repeatability may not be the best reason to choose this filament.
Engineering trade-offs
- The report should be read as a suitability warning rather than a general-purpose recommendation.
Base-material printing guidance
| Guidance | Minimum | Recommended | Maximum | Unit |
|---|---|---|---|---|
| Nozzle temperature | 195 | 230 | 230 | °C |
| Bed temperature | 60 | 60 | 70 | °C |
| Print speed | 55 | 165 | 165 | mm/s |
| Cooling | 20 | 80 | 85 | % |
| Guidance | Value | Unit |
|---|---|---|
| Cooling guidance | High | |
| Drying temperature | 50 | °C |
| Drying time | 5 | hours |
| Enclosure | Not required | |
| Printer / G-code reference | PrusaCoreOneL | |
| Slicer profile reference | Prusament PLA |
Print workflow checks
- Confirm nozzle temperature, bed temperature, speed, cooling and drying requirements from the manufacturer profile or spool label.
- Print a small validation part before committing to a long, costly or safety-relevant print.
- Orient the part so the governing load does not rely on an unverified or weak engineering axis.
- Layer-adhesion evidence is weak; avoid critical Z-axis loading without additional validation.
- Repeatability is low on the internal scale; run extra validation specimens before relying on the profile.
Decision guidance
- Use this material mainly for low-load, visual or experimental parts.
- Review the listed alternatives if the application needs stronger overall performance.
- Do not choose it as a tensile-strength benchmark material.
- Avoid selecting it for impact-focused testing or shock-loaded designs.
Stronger same-family alternatives
| MaterialID | Material | Manufacturer | Overall | Tensile | Impact |
|---|---|---|---|---|---|
| MAT0069 | ProtoPasta HTPLA Blood of My Enemies PLA Red | ProtoPasta | 100/100 | — | — |
| MAT0079 | Polymaker PolyLight PLA Pro Black | Polymaker | 65/100 | 35/100 | 52/100 |
| MAT0109 | Polymaker PolyMax PLA Black | Polymaker | 64/100 | 32/100 | 62/100 |
Confirm exact settings against the manufacturer profile, spool label and actual printer/material combination. Results do not replace application-specific validation.