Public engineering report

Prusa3D Buddy3D Dark Gold PLA Silk Gold

Material Engineering Report
MaterialID MAT0222
3DPIceland Engineering Platform
3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
Generated 2026-08-25 19:02:26
Public-data contract: This static report contains only allowlisted material identity, public links, canonical MSRP and existing Verified Material Summary / governed score outputs. It excludes raw specimen rows and non-public operational data.
Test coverage
Complete
Engineering axes
6/6
Public MSRP
$25.60 USD/kg

Material identity

MaterialIDMAT0222
MaterialPrusa3D Buddy3D Dark Gold PLA Silk Gold
ManufacturerPrusa3D
Product lineBuddy3D
Base materialPLA
CategoryStandard
Variant / finishSilk
Reinforcement
ColorGold

Governed engineering profile

Overall39/100
Tensile21/100
Impact12/100
Stiffness93/100
Consistency55/100
Layer adhesion15/100
Thermal27/100
Best available axisstiffness

Engineering score profile

Overall
39/100
Tensile
21/100
Impact
12/100
Stiffness
93/100
Consistency
55/100
Layer adhesion
15/100
Thermal
27/100

Engineering radar

TensileImpactStiffnessThermalLayer adhesionConsistency
Selected material
Material average - PLA
Manufacturer average - Prusa3D

All axes use existing governed 0–100 engineering scores. Missing axes are shown at zero and remain listed as n/a elsewhere in the report.

Fixture thermal result

53 °C · score 27/100 · method 3dp-thermal-deflection-fixture-v1
Nearby BlueDOT probe-indicated fixture temperature from a non-standard comparative 3DPIceland method; not ASTM D648, ISO 75, specimen temperature, certified HDT or a manufacturer limit.

Material and manufacturer context

MetricSelected materialMaterial averageManufacturer average
Overall39/10050/10049/100
Tensile21/10029/10031/100
Impact12/10024/10021/100
Stiffness93/10087/10084/100
Consistency55/10079/10079/100
Layer adhesion15/10030/10032/100
Thermal27/100

Verified measurement results

Existing Verified Material Summary outputs. The public renderer does not read raw specimen rows or recalculate these values.

MeasurementAverageStd. deviationCVSamplesConfidence
Tensile upright4.476 MPa3.14 MPa70.2%1010/10
Tensile flat29.224 MPa14.518 MPa49.7%1010/10
Impact upright65.301 kJ/m²25.943 kJ/m²39.7%1010/10
Impact flat182.79 kJ/m²37.063 kJ/m²20.3%1010/10
Stiffness modulus2795.64 MPa
Stiffness deflection1.941 mm

Measurement provenance

Canonical per-module measured dates from SQLite, shown in unambiguous ISO format. Missing dates are not inferred.

ModuleMeasured date
Tensile2026-08-04
Impact2026-08-05
Stiffness2026-08-04
ThermalNot recorded

Engineering interpretation

Summary: Prusa3D Buddy3D Dark Gold PLA Silk Gold has a specialized or limited engineering profile. It is below its material-family average by 10,7 points and below its manufacturer average by 10 points. Its strongest measured axis is Stiffness, while the weakest axis is Impact.
Data-driven review: Prusa3D Buddy3D Dark Gold PLA Silk Gold is best understood as a limited-use material that should be validated carefully before functional use. Compared with the current verified dataset, it ranks better than 12% overall, is below the material-family average by 10,7 points, and is below the manufacturer average by 10 points. Its strongest engineering signal is Stiffness, while Impact is the main limitation to consider before using it for demanding applications.
Best feature
Stiffness
Main limitation
Impact
Dataset position
Better than 12%
207 / 234

Strengths

  • Stiffness: 93/100. Stiffness is a relative advantage in this comparison group.

Limitations

  • Tensile: 21/100. Avoid using this as the primary choice for tensile-loaded parts.
  • Impact: 12/100. Avoid high impact or shock-loaded components without additional validation.
  • Consistency: 55/100. Repeatability may not be the best reason to choose this filament.
  • Layer adhesion: 15/100. Z-axis performance should be treated with caution.

Engineering trade-offs

  • Stiffness is useful for shape stability, but impact tolerance is a separate limitation.
  • The report should be read as a suitability warning rather than a general-purpose recommendation.

Recommended applications

  • Rigid brackets, fixtures and shape-stable prototypes
  • Cosmetic parts, concept models or low-load prototypes
  • Avoid high tensile load applications
  • Avoid high impact components

Metric rankings and percentiles

MetricScoreRankPercentile
Overall39/100207 / 234Better than 12%
Tensile21/100178 / 226Better than 22%
Impact12/100202 / 226Better than 11%
Stiffness93/10059 / 223Better than 74%
Consistency55/100227 / 231Better than 2%
Layer adhesion15/100168 / 226Better than 26%
Thermal27/100131 / 209Better than 38%

Decision guidance

Better alternatives

MaterialIDMaterialManufacturerOverallTensileImpact
MAT0069ProtoPasta HTPLA Blood of My Enemies PLA RedProtoPasta100/100
MAT0079Polymaker PolyLight PLA Pro BlackPolymaker65/10035/10052/100
MAT0109Polymaker PolyMax PLA BlackPolymaker64/10032/10062/100

Peer context

Highest-scoring same-base-material peers from the current governed dataset. This context is descriptive and is not recalculated by the public renderer.

MaterialIDMaterialManufacturerOverallTensileImpact
MAT0069ProtoPasta HTPLA Blood of My Enemies PLA RedProtoPasta100/100
MAT0079Polymaker PolyLight PLA Pro BlackPolymaker65/10035/10052/100
MAT0109Polymaker PolyMax PLA BlackPolymaker64/10032/10062/100
MAT0080Polymaker PolySonic PLA Pro BluePolymaker64/10030/10058/100
MAT0076BambuLab Tough+ PLA Tough+ BlackBambuLab63/10026/10059/100
MAT0108Polymaker PolyLight PLA BlackPolymaker61/10033/10014/100
MAT0074Winkle Matte PLA Matte RedWinkle60/10034/100
MAT0122Add:North Enhanced PLA ClearAdd:North59/10040/10010/100

Public links

Methodology and limitations

Results are comparative 3DPIceland measurements from home-built test equipment. Thermal is a nearby BlueDOT probe-indicated fixture temperature, not ASTM D648, ISO 75 or specimen temperature. Missing evidence remains n/a. Scores and test results are not recalculated by this publishing layer and do not replace certified manufacturer datasheets or accredited laboratory testing.