Public engineering report

MatterHackers NylonX PA12 CF Black

Material Engineering Report
MaterialID MAT0019
3DPIceland Engineering Platform
3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
Generated 2026-08-25 19:02:26
Public-data contract: This static report contains only allowlisted material identity, public links, canonical MSRP and existing Verified Material Summary / governed score outputs. It excludes raw specimen rows and non-public operational data.
Test coverage
Complete
Engineering axes
6/6
Public MSRP
$126.00 USD/kg

Material identity

MaterialIDMAT0019
MaterialMatterHackers NylonX PA12 CF Black
ManufacturerMatterHackers
Product lineNylonX
Base materialPA12
CategoryEngineering
Variant / finish
ReinforcementCF
ColorBlack

Governed engineering profile

Overall42/100
Tensile32/100
Impact22/100
Stiffness50/100
Consistency71/100
Layer adhesion33/100
Thermal66/100
Best available axisconsistency

Engineering score profile

Overall
42/100
Tensile
32/100
Impact
22/100
Stiffness
50/100
Consistency
71/100
Layer adhesion
33/100
Thermal
66/100

Engineering radar

TensileImpactStiffnessThermalLayer adhesionConsistency
Selected material
Material average - PA12
Manufacturer average - MatterHackers

All axes use existing governed 0–100 engineering scores. Missing axes are shown at zero and remain listed as n/a elsewhere in the report.

Fixture thermal result

131 °C · score 66/100 · method 3dp-thermal-deflection-fixture-v1
Nearby BlueDOT probe-indicated fixture temperature from a non-standard comparative 3DPIceland method; not ASTM D648, ISO 75, specimen temperature, certified HDT or a manufacturer limit.

Material and manufacturer context

MetricSelected materialMaterial averageManufacturer average
Overall42/10045/10042/100
Tensile32/10032/10032/100
Impact22/10040/10022/100
Stiffness50/10054/10050/100
Consistency71/10075/10071/100
Layer adhesion33/10021/10033/100
Thermal66/100

Verified measurement results

Existing Verified Material Summary outputs. The public renderer does not read raw specimen rows or recalculate these values.

MeasurementAverageStd. deviationCVSamplesConfidence
Tensile upright12.735 MPa2.373 MPa18.6%1010/10
Tensile flat38.175 MPa4.81 MPa12.6%1010/10
Impact upright33.336 kJ/m²13.673 kJ/m²41%1010/10
Impact flat410.531 kJ/m²169.697 kJ/m²41.3%88/10
Stiffness modulus1512.395 MPa
Stiffness deflection3.588 mm

Measurement provenance

Canonical per-module measured dates from SQLite, shown in unambiguous ISO format. Missing dates are not inferred.

ModuleMeasured date
TensileNot recorded
ImpactNot recorded
StiffnessNot recorded
ThermalNot recorded

Engineering interpretation

Summary: MatterHackers NylonX PA12 CF Black has a specialized or limited engineering profile. It is below its material-family average by 2,8 points and above its manufacturer average by 0 points. Its strongest measured axis is Consistency, while the weakest axis is Impact.
Data-driven review: MatterHackers NylonX PA12 CF Black is best understood as a repeatable material for cosmetic, concept and low-load prototype work. Compared with the current verified dataset, it ranks better than 20% overall, is roughly aligned with the material-family average, and is roughly aligned with the manufacturer average. Its strongest engineering signal is Consistency, while Impact is the main limitation to consider before using it for demanding applications.
Best feature
Consistency
Main limitation
Impact
Dataset position
Better than 20%
188 / 234

Strengths

  • Layer adhesion: 33/100. Z-axis bonding is better than the material-family context.
  • Consistency: 71/100. Repeatability is one of the stronger signals in this material profile.

Limitations

  • Tensile: 32/100. Avoid using this as the primary choice for tensile-loaded parts.
  • Impact: 22/100. Avoid high impact or shock-loaded components without additional validation.
  • Layer adhesion: 33/100. Z-axis performance should be treated with caution.

Engineering trade-offs

  • Good repeatability does not compensate for low tensile capability in load-bearing designs.
  • The report should be read as a suitability warning rather than a general-purpose recommendation.

Recommended applications

  • Repeatable print jobs and production-style batches
  • Cosmetic parts, concept models or low-load prototypes
  • Avoid high tensile load applications
  • Avoid high impact components

Metric rankings and percentiles

MetricScoreRankPercentile
Overall42/100188 / 234Better than 20%
Tensile32/10080 / 226Better than 65%
Impact22/100111 / 226Better than 51%
Stiffness50/100205 / 223Better than 9%
Consistency71/100195 / 231Better than 16%
Layer adhesion33/10071 / 226Better than 69%
Thermal66/1007 / 209Better than 97%

Decision guidance

Better alternatives

MaterialIDMaterialManufacturerOverallTensileImpact
MAT0214Eryone Standard Black PA12 CF BlackEryone53/10043/10046/100
MAT0167BambuLab Basic PA12 PAHT CF BlackBambuLab51/10039/10041/100
MAT0020Extrudr DuraPro PA12 BlackExtrudr50/10034/10050/100

Peer context

Highest-scoring same-base-material peers from the current governed dataset. This context is descriptive and is not recalculated by the public renderer.

MaterialIDMaterialManufacturerOverallTensileImpact
MAT0214Eryone Standard Black PA12 CF BlackEryone53/10043/10046/100
MAT0167BambuLab Basic PA12 PAHT CF BlackBambuLab51/10039/10041/100
MAT0020Extrudr DuraPro PA12 BlackExtrudr50/10034/10050/100
MAT0209Eryone Standard Black PA12 GF BlackEryone49/10033/10067/100
MAT0022Fillamentum FX256 PA12 ClearFillamentum45/10028/10047/100
MAT0239Yasin Standard Black PA12 CF BlackYasin41/10033/10025/100
MAT0196Extrudr DuraPro Black PA12 CF BlackExtrudr40/10028/10044/100
MAT0021Yasin Standard Black PA12 BlackYasin31/10022/10013/100

Public links

Methodology and limitations

Results are comparative 3DPIceland measurements from home-built test equipment. Thermal is a nearby BlueDOT probe-indicated fixture temperature, not ASTM D648, ISO 75 or specimen temperature. Missing evidence remains n/a. Scores and test results are not recalculated by this publishing layer and do not replace certified manufacturer datasheets or accredited laboratory testing.