Public manufacturer report

Fillamentum

Portfolio coverage, product-level engineering context and comparative public manufacturer positioning.

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-13 19:31:19

Public-data contract: portfolio statistics and positions use only explicitly allowlisted MaterialIDs and existing Verified Material Summary scores. No measurement or score is recalculated.
Public materials
2
Product lines
2
Material types
2
With results
2
Complete profiles
1
Average overall
41/100
Public global rank
19 of 22
Benchmark manufacturers
22

Manufacturer overview and public global position

MaterialsProduct linesTypesWith resultsCompleteAverage overallGlobal rankPortfolio leaderStrongest axisWith MSRPWith video
2222141/10019 of 22Fillamentum FX256 PA12 Clearconsistency22
Manufacturer website: Open manufacturer website

Category position by base material

Base materialPublic manufacturer positionAverage overallScored products
PA124 of 641/1001
PLAn/an/a0

Overall leaders

Fillamentum FX256 PA12 Clear
41/100

Consistency leaders

Fillamentum FX256 PA12 Clear
85/100
Fillamentum Extrafill Brown PLA Glitter Brown
85/100

Product-level engineering context

MaterialIDMaterialProduct lineTypeReinforcementRigid coverageEngineering axesOverallTensileImpactIzodCharpyStiffnessConsistencyLayer adhesionStrongest axisMSRP USD/kgProductVideo
MAT0022Fillamentum FX256 PA12 ClearFX256PA12Complete; 5/5 score families; Izod/Charpy 2/2 measured, 2/2 scored; Overall eligible; policy engineering-score-v70-17/841/10028/100—10/10012/10026/10085/10054/100consistency$46.74Product pageVideo review
MAT0121Fillamentum Extrafill Brown PLA Glitter BrownExtrafillPLAPartial; 3/5 score families; Izod/Charpy 0/2 measured, 0/2 scored; Overall unavailable: missing measurements or references; policy engineering-score-v70-13/8—36/100————85/10048/100consistency$28.75Product pageVideo review
Results are comparative 3DPIceland measurements and do not replace manufacturer datasheets or accredited laboratory testing.

Testing methodology · Engineering methodology whitepaper · Download PDF

Fillamentum FX256 PA12 Clear

Izod and Charpy Impact Strength

Charpy Impact Strength · 2026-10-07
Instrument readings in kJ/m²
Mean 9.334 kJ/m²; Std. Dev 1.074 kJ/m²; CV 11.507%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Izod Impact Strength · 2026-10-07
Instrument readings in kJ/m²
Mean 7.858 kJ/m²; Std. Dev 0.698 kJ/m²; CV 8.878%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Score policy engineering-score-v70-1: Overall requires tensile, stiffness, consistency, layer adhesion and the Izod/Charpy impact family, each with equal weight. Both impact methods and configured versioned references are required. Missing results and unconfigured scores remain n/a. Legacy Impact is historical only; thermal remains separate. Engineering-axis counts describe displayed evidence, not Overall completeness.